1、关闭减压阀前的闸阀,开启减压阀后的闸阀,制造下游低压环境;
2、将调节螺钉按逆时针旋转至上位置(相对低出口压力),关闭减压阀后闸阀;
3、慢慢开启减压阀前的闸阀至全开;
4、顺时针慢慢旋转调节螺钉,将出口压力调至所需要的压力(以阀后表压为准);调整好后,将锁紧
螺母锁紧,打开减压阀后闸阀;
5、如在调整时出口压力高于设定压力,须从开始重新调整,即只能从低压向高压调。
台湾WILSHEN伟圣单向减压阀
RCG系列单向减压阀部分型号:
RCG-03-1-31 RCT-03-1-31
RCG-06-1-31 RCT-06-1-31
RCG-10-1-31 RCT-10-1-31
RCG-03-2-31 RCT-03-2-31
RCG-06-2-31 RCT-06-2-31
RCG-10-2-31 RCT-10-2-31
RCG-03-3-31 RCT-03-3-31
RCG-06-3-31 RCT-06-3-31
RCG-10-3-31 RCT-10-3-31
RCG-03-1-30 RCT-03-1-30
RCG-06-1-30 RCT-06-1-30
RCG-10-1-30 RCT-10-1-30
RCG-03-2-30 RCT-03-2-30
RCG-06-2-30 RCT-06-2-30
RCG-10-2-30 RCT-10-2-30
RCG-03-3-30 RCT-03-3-30
RCG-06-3-30 RCT-06-3-30
RCG-10-3-30 RCT-10-3-30 1322
台湾WILSHEN伟圣减压阀
RG系列减压阀部分型号:
RG-03-1-31 RT-03-1-31
RG-06-1-31 RT-06-1-31
RG-10-1-31 RT-10-1-31
RG-03-2-31 RT-03-2-31
RG-06-2-31 RT-06-2-31
RG-10-2-31 RT-10-2-31
RG-03-3-31 RT-03-3-31
RG-06-3-31 RT-06-3-31
RG-10-3-31 RT-10-3-31
RG-03-1-30 RT-03-1-30
RG-06-1-30 RT-06-1-30
RG-10-1-30 RT-10-1-30
RG-03-2-30 RT-03-2-30
RG-06-2-30 RT-06-2-30
RG-10-2-30 RT-10-2-30
RG-03-3-30 RT-03-3-30
RG-06-3-30 RT-06-3-30
RG-10-3-30 RT-10-3-30 1322旺旺发到本帖
台湾WILSHEN伟圣压力控制阀
HC型压力控制阀部分型号:
HCG-03-A-1 HCG-06-A-1 HCG-10-A-1
HCT-03-A-1 HCT-06-A-1 HCT-10-A-1
HCG-03-A-2 HCG-06-A-2 HCG-10-A-2
HCT-03-A-2 HCT-06-A-2 HCT-10-A-2
HCG-03-A-3 HCG-06-A-3 HCG-10-A-3
HCT-03-A-3 HCT-06-A-3 HCT-10-A-3
HCG-03-A-4 HCG-06-A-4 HCG-10-A-4
HCT-03-A-4 HCT-06-A-4 HCT-10-A-4
H型压力控制阀部分型号:
HG-03-A-4 HT-03-A-4
HG-06-A-4 HT-06-A-4
HG-10-A-4 HT-10-A-4
HG-03-A-1 HT-03-A-1
HG-06-A-1 HT-06-A-1
HG-10-A-1 HT-10-A-1
HG-03-A-2 HT-03-A-2
HG-06-A-2 HT-06-A-2
HG-10-A-2 HT-10-A-2
HG-03-A-3 HT-03-A-3
HG-06-A-3 HT-06-A-3
HG-10-A-3 HT-10-A-3
台湾WILSHEN伟圣卸载溢流阀
BUCG系列卸载溢流阀部分型号:
BUCG-03-1-10-1PN-A